Features
One valve performs two functions.
- It leaks after completely closing.
- It is most suitable for preventing countercurrent of oil in the rotary pump.
- The valve can be opened and closed simply by turning the power on and off.
- It is suitable as a safety valve for blackout situation.
- The mounting condition is optional.
- It is compact (small and lightweight).
Specifications
Applicable pressure | Atmospheric pressure to 10⁻² Pa |
Material | 06P: BsBm 08P: Al, Other mild steel cast iron |
Leak volume | 6.7×10-6Pa・m3 / sec |
Voltage | 100V or 200V |
Operating temperature | 0 to 60℃ |
Flange | Vacuum flange JIS B-2290 without groove |
Dimensional drawing
Model |
Diameter (A) |
Face‐to‐face dimension (B) |
Total length (C) |
Flange (JIS-2290) |
|||
Outer diameter (D) |
P. C. D. (E) |
Bolt hole (F) |
Bolt hole (G) | ||||
AL-06P | 17φ | 30 | 150 | 40□ | 43 | 4-M4 | 4-M4 |
AL-08P | 25φ | 37 | 175 | 50□ | 54 | 4-M6 | 4-M6 |
AL-1P | 25φ | 60 | 188 | 90 | 70 | 4-9φ | 4-M8 |
AL-2P | 50φ | 80 | 253 | 120 | 100 | 4-9φ | 4-M8 |
AL-3P | 80φ | 100 | 323 | 160 | 135 | 4-12φ | 4-M10 |
-
The model dimensions indicate the effective port diameter of the valve in inches.
-
The body of AL-06 and AL-08 is square.
Remarks
This electromagnetic vacuum valve is a pilot-type automatic vacuum valve that uses the differential pressure between atmospheric pressure and vacuum, it opens only when the differential pressure of the valve seat is small, and prevents sudden flow of gas to the high vacuum side at restart. It is a simple structure with only a valve(SCS-13) and a diaphragm, and can be easily maintained by removing the bonnet.